ZZ
NF5030
delivery time:2-3 weeks
Product characteristics | |
---|---|
Electrical design | NAMUR |
Output function | normally closed |
Sensing range [mm] | 4 |
Housing | Threaded type |
Dimensions [mm] | M12 x 1 / L = 30 |
Electrical data | |
Connection at circuit amplifier | yes |
Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
Nominal voltage DC [V] | 8.2; (1kΩ) |
Supply voltage DC [V] | 7.5...30; (when used outside the hazardous area) |
Current consumption [mA] | < 1; (disabled; conductive: > 2,1) |
Protection class | III |
Outputs | |
Electrical design | NAMUR |
Output function | normally closed |
Permanent current rating of switching output DC [mA] | 30; (when used outside the hazardous area) |
Switching frequency DC [Hz] | 1500 |
Monitoring range | |
Sensing range [mm] | 4 |
Real sensing range Sr [mm] | 4 ± 10 % |
Accuracy / deviations | |
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] | 1...15 |
Switch-point drift [% of Sr] | -10...10 |
Operating conditions | |
Ambient temperature [°C] | -20...80 |
Protection | IP 67 |
Tests / approvals | |
Approval | PTB 01 ATEX 2191; BVS 04 ATEX E153; TIIS TC16107; IECEx BVS 06.0003 |
ATEX marking | II 1G Ex ia IIC T6 Ga Ta: -20...70° C |
II 1G Ex ia IIC T5 Ga Ta: -20...80° C | |
II 1D Ex ia IIIC T90° C Da Ta: -20...70° C | |
II 1D Ex ia IIIC T100° C Da Ta: -20...80° C | |
EMC | |
Shock/vibration resistance | 30 g (11 ms) / 10-55 Hz (1 mm) |
MTTF [years] | 4736 |
Safety classification | |
Max. internal capacitance [nF] | 141 |
Max. internal inductance [µH] | 134 |
Mechanical data | |
Weight [g] | 253.5 |
Housing | Threaded type |
Mounting | non-flush mountable |
Dimensions [mm] | M12 x 1 / L = 30 |
Thread designation | M12 x 1 |
Material | stainless steel; PBT |
Accessories | |
Items supplied | |
Remarks | |
Pack quantity | 1 pcs. |