LC1D09B7C
contactor TeSys LC1-D - 3 poles - AC-3 440V
9 A - coil 24 V AC

Main

Range of product TeSys D
Product or component
type
Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-3
Control circuit type AC
Coil type AC 50/60 Hz
Poles description 3P
Pole contact composition 3 NO
[Ie] rated operational
current
25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
Motor power kW 4 kW at 380...400 V AC 50/60 Hz
2.2 kW at 220...230 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
4 kW at 415...440 V AC 50/60 Hz
Motor power hp 0.5 hp at 115 V AC 60 Hz for 1P motors conforming
to CSA
0.5 hp at 115 V AC 60 Hz for 1P motors conforming
to UL
1 hp at 230/240 V AC 60 Hz for 1P motors conforming
to CSA
1 hp at 230/240 V AC 60 Hz for 1P motors conforming
to UL
2 hp at 200/208 V AC 50/60 Hz for 3P motors conforming
to CSA
2 hp at 200/208 V AC 50/60 Hz for 3P motors conforming
to UL
2 hp at 230/240 V AC 50/60 Hz for 3P motors conforming
to CSA
2 hp at 230/240 V AC 50/60 Hz for 3P motors conforming
to UL
5 hp at 460/480 V AC 50/60 Hz for 3P motors conforming
to CSA
5 hp at 460/480 V AC 50/60 Hz for 3P motors conforming
to UL
7.5 hp at 575/600 V AC 50/60 Hz for 3P motors conforming
to CSA
7.5 hp at 575/600 V AC 50/60 Hz for 3P motors conforming
to UL
[Uc] control circuit voltage 24 V AC 50/60 Hz
Connections - terminals Control circuit: ring lugs - external diameter: 8 mm
Control circuit: spring terminal 1 cable 2.5 mm² - cable
stiffness: flexible - without cable end
Control circuit: spring terminal 2 cable 2.5 mm² - cable
stiffness: flexible - without cable end
Power circuit: ring lugs - external diameter: 8 mm
Power circuit: spring terminal 1 cable 2.5 mm² - cable
stiffness: flexible - without cable end
Power circuit: spring terminal 2 cable 2.5 mm² - cable
stiffness: flexible - without cable end
Control circuit: screw clamp terminal 1 cable 1...4
mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminal 2 cable 1...4
mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminal 1 cable 1...4
mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminal 2 cable 1...2.5
mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminal 1 cable 1...4
mm² - cable stiffness: solid - without cable end
Control circuit: screw clamp terminal 2 cable 1...4
mm² - cable stiffness: solid - without cable end
Power circuit: screw clamp terminal 1 cable 1...4
mm² - cable stiffness: flexible - without cable end
Power circuit: screw clamp terminal 2 cable 1...4
mm² - cable stiffness: flexible - without cable end
Power circuit: screw clamp terminal 1 cable 1...4
mm² - cable stiffness: flexible - with cable end
Power circuit: screw clamp terminal 2 cable 1...2.5
mm² - cable stiffness: flexible - with cable end
Power circuit: screw clamp terminal 1 cable 1...4
mm² - cable stiffness: solid - without cable end
Power circuit: screw clamp terminal 2 cable 1...4
mm² - cable stiffness: solid - without cable end
Coil technology Without built-in bidirectional peak limiting diode suppressor
Protective cover With
Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
Control circuit voltage limits 0.3...0.6 Uc at 60 °C drop-out 50/60 Hz
0.8...1.1 Uc at 60 °C operational 50 Hz
0.85...1.1 Uc at 60 °C operational 60 Hz
[Ui] rated insulation voltage 600 V for control circuit certifications CSA
600 V for control circuit certifications UL
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for control circuit conforming to IEC 60947-1
690 V for power circuit conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
Mounting support Plate
Rail
Flame retardance V1 conforming to UL 94
Tightening torque Control circuit: 1.7 nm - on screw clamp terminal - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Power circuit: 1.7 nm - on screw clamp terminal - with screwdriver flat Ø 6 mm
Power circuit: 1.7 nm - on screw clamp terminal - with screwdriver Philips No 2
[Ue] rated operational voltage <= 690 V AC 25...400 Hz for power circuit
[Ith] conventional free air thermal current 10 A at <= 60 °C for control circuit
25 A at <= 60 °C for power circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
250 A DC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1
20 A gG at <= 690 V coordination type 2 for power circuit
25 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 2.5 mOhm at 50 Hz - Ith 25 A for power circuit
Power dissipation per pole 0.2 W AC-3
1.56 W AC-1
Inrush power in VA 70 VA at 20 °C (cos φ 0.75)
Hold-in power consumption in VA 7 VA at 20 °C (cos φ 0.3) 50 Hz
Operating time 20 ms opening
12...22 ms closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO
13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO
13849-1
Mechanical durability 15000000 cycles
Operating rate 3600 cyc/h at <= 60 °C
Minimum switching current 5 mA for control circuit
Minimum switching voltage 17 V for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
Insulation resistance > 10 MOhm for control circuit
Height 77 mm
Width 45 mm
Depth 84 mm
Product weight 0.5 kg
Standards CSA C22-2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications BV
CCC
CSA
DNV (Det Norske Veritas)
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
IP degree of protection IP2x conforming to IEC 60529
IP2x conforming to VDE 0106
Protective treatment TH (pollution degree: 3) conforming to IEC 60068
Ambient air temperature for operation -5...60 °C
Ambient air temperature for storage -60...80 °C
Permissible ambient air temperature around the device -40...70 °C at Uc
Operating altitude 3000 m without derating in temperature
Fire resistance 850 °C conforming to IEC 60695-2-1
Shock resistance 10 gn contactor opened
15 gn contactor closed
Vibration resistance 2 gn 5...300 Hz contactor opened
4 gn 5...300 Hz contactor closed
Heat dissipation 2...3 W at 50/60 Hz for control circuit



Contact Information:

 

Wechat: +86 133 5926 9377

Email:  rig123@rig123.com

Skype:  liuyongjie67

QQ: 526354062

 

If you have any questions,pls do not hesitate to contact us .

 

Attention: Please kindly leave us your phone number ,and also a full and accurate shipping address. 

 

Remark : please kindly add our email to your "white-list" or sign"important" then you can get our message successfully every time,like special offer, promotion sale ,technic info , and so on ,thanks !

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
View History
Business time
9:00-22:00
  • Email:support@rig123.com