Specification | 02 | 03 | |||
working pressure (MPa) | Oil ports P、A、B | 35 | 31.5 | ||
Oil ports T | 10 | 10 | |||
Max. Flow | (L/min) | 80 | 120 | ||
Working fluid | Mineral oil;phosphate-ester | ||||
Fluid temp. | (℃) | -20~70 | |||
Viscosity | (mm²/s) | 2.8~100 | |||
Working voltage (v) | DC | 12 | 24 | ||
AC | 110V/50Hz | 220V/50Hz | |||
Max.Switch frequency | (T/h) | 15000(DC) | 7200(AC) | ||
Insulation grade | IP65 | ||||
Weight (kg) | Single solenoid | 1.45(DC) | 1.4(AC) | 5.1(DC) | 4.3(AC |
Double solenoids | 1.95(DC) | 1.9(AC) | 6.7(DC) | 5.1(AC) | |
Cleanliness |
The maximum allowable cleanliness of the oil should be according to 9th degree of Standard NAS1638.lt is suggested that the minimum filter rating should be β10≥75。 |