LW36-126/T3150-40 Outdoor High Voltage AC SF6 Circuit Breaker
1
  • LW36-126/T3150-40 Outdoor High Voltage AC SF6 Circuit Breaker
2
views: 235

LW36-126/T3150-40 Outdoor High Voltage AC SF6 Circuit Breaker

Rate:
0.0000/5

( 0 reviews )

Item NO.: V021457 MOQ: 0
Weight:    0kgs
Package Size:  
 Price:
$0.00
 Qty:
      $0.00
 Shipping:   Calculate Shipping Cost
LW36-126/T3150-40 Outdoor HV AC SF6 Circuit Breaker is a kind of switching equipment with SF6 gas as insulating medium, which can close, load and interrupt the normal current of operation circuit in HV transmission line, and also can close, load and interrupt the short circuit and overload current in the specified time. Porcelain pillar type is adopted in the structure, which can be operated by three-phase opening, closing and automatic reclosing to realize the control and protection of transmission lines of 50HZ, 126KV and below.

The circuit breaker adopts the principle of self-energy arc extinguishing with spring mechanism. When the circuit breaker receives the opening instruction, the rigid components such as cylinder, moving arc contact and tie rod move downward under the action of the spring force of the opening. In the process of movement, the static main contact is separated from the main contact, and the current is transferred to the arc contact, then the arc contact is separated, and the arc is generated between the dynamic and static arc contacts. When short-circuit current is interrupted, the arc energy between arc contacts is large because of the high current value. The arc heat flow is injected into the thermal expansion chamber to exchange heat in the thermal expansion chamber and form low temperature and high pressure gas. At this time, the one-way valve in the arc extinguishing chamber closes because the pressure of the thermal expansion chamber is greater than that of the auxiliary pressure chamber. When the current is zero, the high-pressure gas in the thermal expansion chamber blows back to the fracture to extinguish the arc. When switching off small current (usually below several thousand amperes), because of the small arc energy, the pressure rise in the expansion chamber is slower than that in the auxiliary chamber. The one-way valve opens and the compressed gas in the auxiliary chamber enters the expansion chamber, which produces gas blowing and extinguishes the arc when the current passes zero.


Using self-energy arc extinguishing principle, the operation work is small and the impact is small.
With spring mechanism, the performance of the mechanism has nothing to do with temperature, small wear and stable performance.
The optimized structure of arc extinguishing chamber and contact motion curve have high interruption reliability.
No reburning and re-breakdown occurs when capacitive current is switched off.
The optimized design of pole column and braced frame has high seismic capacity.
It has high reliability, long average trouble-free time and low maintenance cost.
On-site installation and debugging is fast, only 1 to 2 days;
Low operating noise, suitable for residential areas.


No Items unit parameter
1 Rated voltage kV 126
2 Rated power frequency withstand voltage (1 min) Intersection and opposition

kV 230
Fracture kV 230+73*
3 Rated lightning impulse withstand voltage Intersection and opposition kV 550
Fracture kV 550+103*
4 Power Frequency Tolerance Voltage (5min) at SF6 Zero Meter Voltage kV 95
5 Rated Frequency Hz 50
6 Rated current A 3150
7 Rated short circuit breaking current kA 40
8 First open pole coefficient 1.5
9 DC Component of Rated Short Circuit Opening Current 不小于41%
10 Rated short circuit switching current (peak value) kA 100
11 Rated short-term withstand current (RMS) kA 40
12 Rated peak tolerance current (peak) kA 100
13 Rated short circuit duration s 4
14 Rated out-of-step switching-on current kA 3(OP1) ,10(OP2)
15 Close-zone fault switching-on current kA 3630
16 Disconnecting Current of Dissimilar Grounding Fault kA 34.8
17 Rated line charging switching current A 31.5
18 No overhaul full capacity interruption times 20(或额定电流开断次数:3000次)
19 Rated operation sequence O-0.3s-CO-180s-CO
20 Rated Sulfur Hexafluoride Gas Pressure (20 C Meter Pressure) MPa 0.6
21 Alarm/Block Pressure (20 C Meter Pressure) MPa 0.55/0.50
22 Annual leakage rate of SF6 gas %/Y 0.5
23 Gas moisture content Handover Acceptance Value μL/L 150
Running allowable value μL/L 300
24 Main circuit resistance μΩ 35
25 Mechanical life 6000
26 Radio interference level (1.1 Ur)/ μV 500
Bitmaphttp://www.chinatcs.com/Files/lw3601.jpg
27 Permissible Partial Discharge Intensity (1.2Ur) pC 5
28 Noise (2 m and 1.5 m above the sound source level) dB 90

 