Home » News center » 3RV1011-1KA10 3RV1011-1JA10 3RV1011-1FA10
3RV1011-1KA10 3RV1011-1JA10 3RV1011-1FA10
      Promulgator :admin      Time:2016-10-29
Inquiry Photo Description Model Technical parameters Certification Remark
3RV MCB Size S0 3RV1021-1AA10
Max. Operating Voltage 690VAC

REL. 1.1-1.6A, Class 10 screw connection increased breaking capacity , Electrical Power 0.55KW, Short-circuit tripping current 19A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0KA10
Max. Operating Voltage 690VAC

REL. 0.9-1.25A, Class 10 screw connection increased breaking capacity , Electrical Power 0.37KW, Short-circuit tripping current 15A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0JA10
Max. Operating Voltage 690VAC

REL. 0.7-1A, Class 10 screw connection increased breaking capacity , Electrical Power 0.25KW, Short-circuit tripping current 12A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0HA10
Max. Operating Voltage 690VAC

REL. 0.55-0.8A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 9.6A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0GA10
Max. Operating Voltage 690VAC

REL. 0.45-0.63A, Class 10 screw connection increased breaking capacity , Electrical Power 0.18KW, Short-circuit tripping current 7.6A,415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0FA10
Max. Operating Voltage 690VAC

REL. 0.35-0.5A, Class 10 screw connection increased breaking capacity , Electrical Power 0.12KW, Short-circuit tripping current 6A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0EA10
Max. Operating Voltage 690VAC

REL. 0.28-0.4A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 4.8A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0DA10
Max. Operating Voltage 690VAC

REL. 0.22-0.32A, Class 10 screw connection increased breaking capacity , Electrical Power 0.09KW, Short-circuit tripping current 3.8A, Breaking capacity at 415V:Icu=100KA


IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0DA10
Max. Operating Voltage 690VAC

REL. 0.18-0.25A, Class 10 screw connection increased breaking capacity , Electrical Power 0.06KW, Short-circuit tripping current 3A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0BA10
Max. Operating Voltage 690VAC

REL. 0.14-0.2A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 2.4A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S0 3RV1021-0AA10
Max. Operating Voltage 690VAC

REL. 0.11-0.16A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 1.9A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1KA10
Max. Operating Voltage 690VAC

REL. 9-12A, Class 10 screw connection increased breaking capacity , Electrical Power 5.5KW, Short-circuit tripping current 144A, Breaking capacity at 415V:Icu=50KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1JA10
Max. Operating Voltage 690VAC

REL. 7-10A, Class 10 screw connection increased breaking capacity , Electrical Power 4KW, Short-circuit tripping current 120A, Breaking capacity at 415V:Icu=50KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1HA10
Max. Operating Voltage 690VAC

REL. 5.5-8A, Class 10 screw connection increased breaking capacity , Electrical Power 3KW, Short-circuit tripping current 96A, Breaking capacity at 415V:Icu=50KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1GA10
Max. Operating Voltage 690VAC

REL. 4.5-6.3A, Class 10 screw connection increased breaking capacity , Electrical Power 2.2KW, Short-circuit tripping current 76A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1FA10
Max. Operating Voltage 690VAC

REL. 3.5-5A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 60A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1EA10
Max. Operating Voltage 690VAC

REL. 2.8-4A, Class 10 screw connection increased breaking capacity , Electrical Power 1.5KW, Short-circuit tripping current 48A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1DA10
Max. Operating Voltage 690VAC

REL. 2.2-3.2A, Class 10 screw connection increased breaking capacity , Electrical Power 1.1KW, Short-circuit tripping current 3.8A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1CA10
Max. Operating Voltage 690VAC

REL. 1.8-2.5A, Class 10 screw connection increased breaking capacity , Short-circuit tripping current 30A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
3RV MCB Size S00 3RV1011-1BA10
Max. Operating Voltage 690VAC

REL. 1.4-2A, Class 10 screw connection increased breaking capacity , Electrical Power 0.75KW, Short-circuit tripping current 24A, Breaking capacity at 415V:Icu=100KA
IEC 947-1, IEC 947-2, IEC 947-4-1, DIN VDE 0660 Part 100, 101, 102 Other models also available, please contact us for details.
 