Inquiry | Photo | Description | Model | Technical parameters | Certification | Remark |
---|---|---|---|---|---|---|
![]() |
3WL Fixed 3P ACB ,with Overcurrent Release |
3WL1212-4CB32-1AA2 |
Rated Current 1250A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB ,with Overcurrent Release |
3WL1210-4CB32-1AA2 |
Rated Current 1000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB ,with Overcurrent Release |
3WL1208-4CB32-1AA2 |
Rated Current 800A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA,with “ETU25B” Overcurrent Release LSI |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1363-4AA41-1AA2 |
Rated Current 6300A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1350-4AA42-1AA2 |
Rated Current 5000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1340-4AA42-1AA2 |
Rated Current 4000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1225-4AA42-1AA2 |
Rated Current 3200A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1225-4AA42-1AA2 |
Rated Current 2500A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1220-4AA42-1AA2 |
Rated Current 2000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1216-4AA42-1AA2 |
Rated Current 1600A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1212-4AA42-1AA2 |
Rated Current 1250A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1210-4AA42-1AA2 |
Rated Current 1000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 4P ACB ,without Overcurrent Release |
3WL1208-4AA42-1AA2 |
Rated Current 800A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1363-4AA31-1AA2 |
Rated Current 6300A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1350-4AA32-1AA2 |
Rated Current 5000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1340-4AA32-1AA2 |
Rated Current 4000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1232-4AA32-1AA2 |
Rated Current 3200A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1225-4AA32-1AA2 |
Rated Current 2500A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1220-4AA32-1AA2 |
Rated Current 2000A,Max. Rated Operating Voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. | |
![]() |
3WL Fixed 3P ACB without Overcurrent Release |
3WL1216-4AA32-1AA2 |
Rated Current 1600A , Max. operating voltage 690VAC Breaking Capacity (Icu; 440V) 800A-6300A = 100kA |
IEC 947-2, DIN VDE 0660 | Other models also available, please contact us for details. |