Home » News center » 3WL1106-3CB46-1AA2 3WL1108-3CB46-1AA2 3WL1112-3CB46-1AA2
3WL1106-3CB46-1AA2 3WL1108-3CB46-1AA2 3WL1112-3CB46-1AA2
      Promulgator :admin      Time:2016-10-29
Inquiry Photo Description Model Technical parameters Certification Remark
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1106-3CB46-1AA2
Rated Current 630A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1108-3CB46-1AA2
Rated Current 800A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1110-3CB46-1AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1112-3CB46-1AA2
Rated Current 1250A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1116-3CB46-1AA2
Rated Current 1600A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1220-3CB46-1AA2
Rated Current 2000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1225-3CB46-1AA2
Rated Current 2500A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1232-3CB46-1AA2
Rated Current 3200A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU27B” Overcurrent Release LSING
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1106-3CB36-4AA2
Rated Current 630A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1108-3CB36-4AA2
Rated Current 800A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1110-3CB36-4AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1112-3CB36-4AA2
Rated Current 1250A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1116-3CB36-4AA2
Rated Current 1600A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1220-3CB36-4AA2
Rated Current 2000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1225-3CB36-4AA2
Rated Current 2500A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 3P ACB with Overcurrent Release 3WL1232-3CB36-4AA2
Rated Current 3200A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 

IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1106-3CB46-4AA2
额Rated Current 630A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1108-3CB46-4AA2
Rated Current 800A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1110-3CB46-4AA2
Rated Current 1000A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
3WL Draw-out 4P ACB ,with Overcurrent Release 3WL1112-3CB46-4AA2
Rated Current 1250A,Max. Rated Operating Voltage 690VAC

Breaking Capacity (Icu; 440V) 630A-1600A = 65kA,800A-3200A = 80kA, with “ETU25B” Overcurrent Release LSI  and 220V AC/DC 
IEC 947-2, DIN VDE 0660 Other models also available, please contact us for details.
 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
Business time
9:00-22:00
  • Email:support@rig123.com